Got a Cross Connection Notice From Halifax Water? Here's What It Means and What to Do Next

If you own or manage a commercial, institutional or multi unit residential building in HRM, sooner or later a letter from Halifax Water's Cross Connection Control Program lands on your desk. It looks official, it mentions backflow, and it usually comes with a deadline. Here's what it actually means.

What a cross connection is

A cross connection is any point where your building's water system could connect with something that isn't drinking water: a boiler, a sprinkler system, an irrigation line, process equipment. If pressure in the city main drops, water can flow backwards from your building into the public supply. That's called backflow, and it's what the program exists to prevent.

What Halifax Water requires

Under the Halifax Water Regulations, approved by the Nova Scotia Utility and Review Board, property owners have to:

  • Remove cross connections that aren't needed
  • Protect the ones that can't be removed with an approved backflow prevention assembly
  • Have every backflow device tested once a year by a certified tester

New industrial, commercial, institutional and multi residential services need a backflow device when the meter is installed. Existing buildings are being brought in through a retrofit program, which is why a lot of property managers are getting notices for the first time. The type of assembly you need depends on the hazard level of the building. A hospital or auto shop is held to a stricter standard than a school or restaurant.

How the annual test works

  1. You get the notice. It includes a Customer Confirmation Number (CCN) for your property.
  2. You hire a certified tester. Halifax Water doesn't do the test. The owner arranges it.
  3. The assembly is tested on site and every reading is documented.
  4. The tester files the report through BSI Online, the system Halifax Water uses to track compliance, using your CCN. There's a filing fee of $15.95 per device.

If an assembly fails, it has to be repaired or replaced and retested.

Why it matters

If contamination of the public supply comes from an unprotected or improper connection, the owner or occupant responsible can be held liable for the damages. A missed test isn't just paperwork. It's exposure.

How Clearstate helps

Forward us your notice. We test each assembly on site, rebuild or replace what fails, file the results and tag the assembly, so you're done until next year.